Abstract:
The sample was digested by microwave with the mixed solution of HNO
3、HCl、HF and H
2O
2 (3+1+1+1), then HNO
3 (1+1) solution was added to dissolve the salt and the solution was diluted for ICP-MS analysis with
103Rh and
232Th as internal standard. The calibration equation was used to eliminate mass spectral interference. The linearity range of Se and the other 7 elements were 0.500-500.0, 0.050-100.0
μg·L
-1, respectively. The detection limits (3
s) of 8 elements were in the range of 0.01-0.8 mg·kg
-1. Recovery rates obtained by standard addition method were in the range of 90.9%-113%, and RSDs (
n=4) were in the range of 0.90%-7.7%. The proposed method was applied to the determination of Cd in nickel concentrate standard substances, giving results in agreement with the certified values.