高级检索

    高效液相色谱-串联质谱法测定食用植物油中4-壬基酚的含量

    HPLC-MS/MS Determination of 4-Nonyl Phenol in Edible Vegetable Oils

    • 摘要: 采用高效液相色谱-串联质谱法测定食用植物油中4-壬基酚的含量。食用植物油样品用乙酸乙酯-环己烷(1+1)混合液溶解,以凝胶渗透色谱净化,在线收集14.0~17.0 min的馏分,于30℃浓缩至近干,加甲醇1.0 mL溶解残余物。在高效液相色谱分离中,以Agilent Poroshell120ec-C18色谱柱为分离柱,以不同体积比的甲醇和0.1%(质量分数)氨水溶液的混合液为流动相进行梯度洗脱。在串联质谱分析中,采用电喷雾负离子源和多反应监测模式检测。所用内标物为4-n-NP-D4,以空白玉米油为基质。4-壬基酚的线性范围为0.25~160 μg·kg-1,方法的检出限(3S/N)为1.00 μg·kg-1。在2.00,5.00,10.00 μg·kg-1等3个浓度水平进行加标回收试验,测得回收率为99.0%~115%,测定值的相对标准偏差(n=6)为4.3%~8.1%。

       

      Abstract: HPLC-MS/MS was applied to the determination of 4-nonyl phenol (4-NP) in edible vegetable oils. The sample of edible vegetable oil was dissolved in mixture of ethyl acetate-cyclohexane (1+1),and then purified by gel permeation chromatography, through collecting the fractions between 14.0 to 17.0 min, and the solution obtained was evaporated to near dryness at 30℃. The residue was taken up and diluted to 1.0 mL with methanol. In HPLC separation, Agilent Poroshell120ec-C18 chromatographic column was used as stationary phase, and the mixture of methanol and 0.1% (mass fraction) ammonia solution mixed in different ratios was used as mobile phase in gradient elution. In MS/MS determination, ESI- and multi-reactions monitor mode were adopted. 4-n-NP-D4 was used as internal standard and blank corn oil was used as matrix. Linearity range of 4-NP was found between 0.25 μg·kg-1 and 160 μg·kg-1 with detection limit (3S/N) of 1.00 μg·kg-1. Tests for recovery were made by standard addition method at 3 concentration levels of 2.00, 5.00, 10.00 μg·kg-1, giving values of recovery and RSD's (n=6) in the ranges of 99.0% to 115% and 4.3% to 8.1% respectively.

       

    /