高级检索

    顶空固相微萃取-气相色谱法测定水中四乙基铅

    GC Determination of Tetraethyl Lead in Water with HS-SPME

    • 摘要: 提出了顶空固相微萃取-气相色谱法测定水中四乙基铅含量的方法。为使固相微萃取达到更高的效率,选用聚二甲基硅氧烷填料(PDMS)作为微萃取的涂层,萃取温度及时间为60 ℃和30 min。用DB-5色谱柱分离,用电子捕获检测器检测。四乙基铅的质量浓度在0.05~20.0 μg·L-1范围内与峰面积呈线性关系,方法的检出限(3S/N)为0.02 μg·L-1。以水样为基体,在3种浓度水平下进行加标回收试验,回收率在87.0%~90.1%之间,测定值的相对标准偏差(n=7)在3.7%~4.2%之间。

       

      Abstract: GC with headspace-solid phase micro-extraction (HS-SPME) was applied to the determination of tetraethyl lead in water. To attain a higher efficiency in SPME, the PDMS fiber was selected as coating for the micro-extraction, and the extraction was carried out at 60 ℃ for 30 min. The analyte were separated on DB-5 chromatography column and detected by ECD. Linear relationship between values of peak area and mass concentration of tetraethyl lead was kept in the range of 0.05-20.0 μg·L-1, with detection limit (3S/N) of 0.02 μg·L-1. Using water sample as matrix, test for recovery was made by addition of standard solution at 3 concentration levels, values of recovery found were in the range of 87.0%-90.1% with RSD′s (n=7) in the range of 3.7%-4.2%.

       

    /