高级检索

    微波消解样品-石墨炉原子吸收光谱法测定土壤中钼量

    GF-AAS Determination of Molybdenum in Soil with Microwave Assisted Sample Digestion

    • 摘要: 土壤样品经盐酸-硝酸(3+1)混合酸微波消解,采用石墨炉原子吸收光谱法测定其中钼含量。以硝酸铵作为基体改进剂,两步灰化温度为800 ℃和1 600 ℃,原子化温度为2 900 ℃。钼的质量浓度在40 μg·L-1以内与其吸光度呈线性关系,检出限(3s/k)为0.69 μg·L-1。应用此法分析了3个土壤标准样品,测定值与认定值相符,相对标准偏差(n=5)在2.6%~5.8%之间。

       

      Abstract: Sample of soil was digested with a mixed acid of HCl and HNO3 (3+1) in a microwave digestor , and the content of molybdenum in the sample solution was determined by GF-AAS. Ammonium nitrate was used as matrix modifier. The temperatures of 2-step ashing were 800 ℃ and 1 600 ℃ and the atomization temperature was 2 900 ℃. Linear relationship between values of absorbance and mass concentration of molybdenum was obtained in the range within 40 μg·L-1, with detection limit (3s/k) of 0.69 μg·L-1. Three CRM′s of soil were analyzed by the proposed method, giving results in consistency with the certified values and values of RSD′s (n=5) obtained were in the range of 2.6%-5.8%.

       

    /