高级检索

    顶空-气相色谱法测定空气中甲醇

    Head-Space GC Determination of Methanol in Air

    • 摘要: 提出了顶空-气相色谱法测定空气中甲醇的方法。选择顶空平衡温度和时间分别为75 ℃和60 min,顶空瓶中样品定容体积为2 mL,用DB-WAX色谱柱分离,火焰离子化检测器检测。甲醇的质量浓度在91.20 mg·L-1以内与其峰面积呈线性关系,检出限(3s)为1.8 mg·L-1。在11.40,22.80,45.60 mg·L-1 3个浓度水平进行加标回收试验,测定值的相对标准偏差(n=6)在2.6%~3.4%之间,方法解吸率在96.5%~98.2%之间。

       

      Abstract: Head-space GC was applied to the determination of methanol in air. The equilibrium temperature and time of head space were set at 75 ℃ and 60 min respectively, with 2 mL of the sample in head-space bottle. The analyte were separated on DB-WAX column and detected by FID. Linear relationship between values of peak area and mass concentration of methanol was kept in the range within 91.20 mg·L-1 with detection limit (3s) of 1.8 mg·L-1. Tests for recovery were made at the concentration levels of 11.40,22.80 and 45.60 mg·L-1 of methanol standard, giving values of RSD′s (n=6) in the ranges of 2.6%-3.4%. The rate of desorption found was in the range of 96.5%-98.2%.

       

    /

    返回文章