氢化物发生-原子荧光光谱法测定钼粉及钼制品中铋和锑
HG-AFS Determination of Bismuth and Antimony in Molybdenum Powder and Products Made of Molybdenum
-
摘要: 采用氢化物发生-原子荧光光谱法测定钼粉及钼制品中痕量铋和锑的含量。样品经盐酸-硝酸混合溶液消解,在盐酸(10+90)溶液中,加入15 g·L-1硼氢化钠溶液使与溶液中铋离子和20 g·L-1硼氢化钠溶液使与溶液中锑离子反应生成氢化物。试样溶液中无需还原剂预还原。荧光强度与铋和锑的质量浓度均在100 μg·L-1以内呈线性关系,方法的检出限(3s/k)分别为0.13,0.03 μg·L-1。应用此法对YSS 003-96氧化钼光谱标准样品进行分析,测定结果与认定值相符合;又分析了钼粉及钼制品样品并以此为基体作回收试验,铋和锑的回收率分别在91.3%~95.7%和94.0%~105.5%之间。Abstract: HG-AFS was applied to the determination of bismuth and antimony in molybdenum powder and products made of molybdenum. Sample was dissolved with mixture of HCl and HNO3, and hydrides of Bi and Sb were generated from HCl (10+90) solution by reacting with 15 g·L-1 and 20 g·L-1 NaBH4 solution respectively. No pre-reduction was necessary for the sample solution. Linear relationships between values of fluorescence intensity and mass concentration of Bi and Sb were found in the same range within 100 μg L-1, with detection limits (3s/k) of 0.13 and 0.03 μg·L-1 respectively. Standard samples of molybdenum oxide (YSS 003-96) were analyzed by the proposed method, results of Bi and Sb found were in consistency with the standard values. Samples of molybdenum powder and products of molybdenum were also analyzed, and tests for recovery were made on the base of these samples as matrixes, values of recovery found were in the ranges of 91.3%-95.7% for Bi and 94.0%-105.5% for Sb respectively.
下载: