用于高灵敏检测人肠道病毒71型的纳米金电化学免疫传感器
Electrochemical Immunosensor Based on Au Nanoparticles for Highly Sensitive Detection of Human Enterovirus 71
-
摘要: 在玻碳电极表面滴加纳米金,通过纳米金(AuNPs)的生物相容性以固定人肠道病毒71型(EV71)抗体从而制备EV71电化学免疫传感器,该电化学免疫传感器可灵敏检测EV71。在pH 7.0的含有0.1 mol·L-1氯化钾和5 mmol·L-1 K3Fe(CN)6/K4Fe(CN)6的磷酸盐缓冲溶液中,通过循环伏安法考察了该免疫传感器的分析性能。当EV71的质量浓度在0.1~80 μg·L-1范围内时,氧化还原探针[Fe(CN6)]3-/4-的氧化峰电流随EV71质量浓度的增大呈线性降低,检出限(3S/N)为0.025 μg·L-1。对20 μg·L-1的EV71抗原标准溶液测定5次,测定值的相对标准偏差为3.0%。以空白样品为基体进行加标回收试验,所得回收率在98.3%~100%之间。Abstract: AuNPs with good biocompatibility were dropped onto the surface of a glassy carbon electrode, then human enterovirus 71 (EV71) immunosensor was formed by immobilization of anti-EV71 on AuNPs. The electrochemical immunosensor could be used for sensitive detection of EV71.The performances of the as-prepared immunosensor were investigated by cyclic voltammetry in PBS (pH 7.0) containing 0.1 mol·L-1 KCl and 5 mmol·L-1 K3Fe(CN)6/K4Fe(CN)6. The oxidation peak current of redox probe, [Fe(CN6)]3-/4-, decreased linearly over the EV71 mass concentration ranged from 0.1 to 80 μg·L-1 with detection limit (3S/N) of 0.025 μg·L-1. Precision of the method was tested at the concentration level of 20 μg·L-1 anti-EV71 standard solution for 5 determinations, value of RSD found was 3.0%. On the base of blank sample, test for recovery was made by standard addition method; values of recovery found were in the range of 98.3%-100%.