高级检索

    数字光栅近红外漫反射法测定复合肥中总磷

    Digital Grating NIR Diffuse Reflectometric Determination of Total Phosphorus in Compound Fertilizer

    • 摘要: 利用数字光栅近红外漫反射技术快速、简便、穿透能力较强的特点建立复合肥中总磷(五氧化二磷)含量的方法,包括定标、建模、验证和应用试验等.结果表明:(1) 检测只需几分钟,而且无需称样和消耗化学试剂.(2) 与磷钼酸喹啉重量分析法相比,其定标标准偏差为0.13%,定标相关系数为0.995 9;验证标准偏差为0.15%,验证相关系数0.994 8;(3) 初步应用该法测定52个复合肥样品,预测标准偏差为0.29%,相关系数为0.985 0,与建模和验证结果相近.

       

      Abstract: Utilizing the peculiarities of strong penetrating ability of NIR diffuse reflectance,conveniency and rapidity of operation,digital grating-NIR diffuse reflectometry was applied to the determination of total phosphorus (expressed as P2O5) in the compound fertilizer,nitrophoska,including testings of standardization,establishment of mathematical model,verification and application.As shown by the experimental results,(1) only few minutes were required for a determination without the necessity of weighing of sample and the consumption of chemical reagents;(2) as compared with the quinoline molybdophosphate gravimetric method,value of standard deviation found in calibration was 0.13%,with correlation coefficient of 0.995 9;value of standard deviation obtained in verification was 0.15% with correlation coefficient of 0.994 8;(3) in the tentative application of the proposed method to the predictive determination of total phosphours in 52 samples of nitrophoska,the predictive standard deviation found was 0.29% with correlation coefficient of 0.985 0,which were very close to the values obtained in calibration and in verification.

       

    /

    返回文章
    返回