基于磷钼蓝反应测定钴-钼催化剂浸渍液中钼离子含量
Determination of Molybdenum Ion in Impregnation Solution of Co-Mo Catalysts Based on the Reaction of Phosphorus Molybdenum Blue
-
摘要: 基于磷钼蓝反应测定钴-钼催化剂浸渍液中钼离子含量.建立了一个流动注射-磷钼蓝分光光度法测定高浓度钼离子的含量,优化后的条件为:① 酸度调节剂为0.5 mol·L-1硫酸溶液;② 载流为超纯水;③ 反应试剂为120 g·L-1磷酸二氢钾、100 g·L-1抗坏血酸及0.3 mol·L-1硫酸的混合液;④ 总流量为2.8 mL·min-1;⑤ 酸度调节盘管长度为20 cm;⑥ 反应盘管长度为250 cm.三氧化钼的质量浓度在10.0~300.0 g·L-1范围内与峰高呈线性关系,检出限(3s/k)为2.0 g·L-1.方法用于钴-钼催化剂钼浸渍液的分析,回收率在99.7%~105%之间,测定值的相对标准偏差(n=11)小于1%.Abstract: Molybdenum ion in impregnation solution of Co-Mo catalysts was determined based on reaction of phosphorus molybdenum blue. A system for measuring high molybdenum ion concentration was established based on the spectrophotometry of flow injection-phosphorus molybdenum blue. The optimized conditions of the system found were as follows:① acidity regulator:0.5 mol·L-1 H2SO4 solution;② carrier:ultrapure water;③ reaction reagent:mixture of 120 g·L-1 KH2PO4,100 g·L-1 Vc and 0.3 mol·L-1 H2SO4;④ total flow rate:2.8 mL·min-1;⑤ length of acidity adjusted coil:20 cm;⑥ length of reaction coil:250 cm. The linear relationship between values of the peak height and the mass concentration of MoO3 was obtained in the range of 10.0-300.0 g·L-1,with detection limit (3s/k) of 2.0 g·L-1. The proposed method was applied to the analysis of samples of impregnation solution of Co-Mo catalysts,giving recovery rates in the range of 99.7%-105% with RSD′s (n=11) less than 1%.