流动注射-分光光度法测定钴钼催化剂浸渍液中高浓度钼离子
FI-Spectrophotometric Determination of Molybdenum of High Concentration in Maceration Extract of Cobalt-Molybdenum Catalysts
-
摘要: 在0.75 mol·L-1硫酸溶液中,抗坏血酸可将Mo6+还原为Mo5+,而硫氰酸铵能与生成的Mo5+显色,在波长465 nm处有最大吸收峰,据此提出了一种流动注射-分光光度法测定钴钼催化剂浸渍液中超高浓度钼离子含量的方法。钼的质量浓度在3.3~93.3 g·L-1范围内与其ΔA呈线性关系,方法的检出限(3s/k)为0.35 g·L-1。方法用于钴钼催化剂浸渍液中钼离子含量的测定,测得方法的回收率在95.0%~101%之间,测定值的相对标准偏差(n=11)小于1%。Abstract: It was found that in 0.75 mol·L-1 H2SO4 solution, Mo6+ was reduced to Mo5+ with ascorbic acid, and a complex between Mo5+ and NH4SCN was formed with its maximum absorption wavelength at 465 nm. Based on these facts, the determination of Mo6+ by flow injection (FI)-spectrophotometry was proposed. Linear relationship between values of ΔA and mass concentration of Mo6+ was kept in the range of 3.3-93.3 g·L-1, with detection limit (3s/k) of the method of 0.35 g·L-1. The proposed method was used in the determination of Mo6+ in sample of maceration extract of cobalt molybdenum catalysts, and values of recovery found were in the range of 95.0%-101%, with RSD (n=6) less than 1%.