高级检索

    流动注射离子交换分离-火焰原子吸收光谱法连续测定铁的形态

    STUDY ON SPECIATION ANALYSIS OF IRON BY FLOW INJECTION-ION EXCHANGE SEPARATION HYPHENATED WITH FAAS

    • 摘要: 研究了一种以NH4F为掩蔽剂掩蔽Fe(Ⅲ),用732型阳离子交换树脂(CSR)吸附Fe(Ⅱ),从而分离测定Fe(Ⅲ)与Fe(Ⅱ)的试验体系.设计了一套新颖的用于该体系的全自动流动注射流路,实现了Fe(Ⅲ)与Fe(Ⅱ)的连续测定.Fe(Ⅲ)和Fe(Ⅱ)的相对标准偏差(n=7)分别为3.37%和1.95%,检出限分别为0.07和0.01 mg·L-1,分析速度为25个样/h.

       

      Abstract: A method of flow injection ion exchange separation followed by flame atomic absorption spectrometry for the speciation analysis of iron was studied in this paper.Iron(Ⅲ) in sample solution was masked by addition of NH4F and Fe(Ⅱ) was adsorbed on the micro column packed with 732# cation exchange resin.The adsorbed Fe(Ⅱ) was then eluted with 6 mol·L-1 HCl solution.Fe(Ⅲ) and Fe(Ⅱ) were successively determined by flame atomic absorption spectrometry.Detection limits of this method were found as 0.07 mg·L-1 for Fe(Ⅲ) and 0.01 mg·L-1 for Fe(Ⅱ),and RSD′s (n=7) of 3.37% for Fe(Ⅲ) and 1.95% for Fe(Ⅱ).Using the proposed method,about 5 samples can be analyzed in an hour.

       

    /