流动注射-电化学发光法测定煤灰中痕量钼(Ⅵ)
Determination of Trace Amount of Molybdenum(Ⅵ) in Coal Ash by Flow Injection-Electrochemiluminescence
-
摘要: 基于钼(Ⅵ)在-0.60 V(vs.Ag/AgCl)电位下在线还原为钼(Ⅲ),且在碱性条件下钼(Ⅲ)与鲁米诺发生化学发光反应,据此提出了流动注射-电化学发光法测定煤灰中痕量钼(Ⅵ)的方法。钼(Ⅵ)的质量浓度与化学发光强度的增加值在5.0×10-7~5.0×10-4g·L-1范围内呈线性关系,检出限(3s/k)为5×10-8g·L-1。对1.0×10-6g·L-1钼(Ⅵ)标准溶液进行11次测定,测定值的相对标准偏差为2.6%。方法可用于煤灰中痕量钼(Ⅵ)的测定,测定值与国标方法测定值相符。Abstract: Based on the on-line reduction of molybdenum(Ⅵ) to molybdenum(Ⅲ) at the potential of -0.60 V(vs.Ag/AgCl), and the chemiluminescence (CL) reaction of luminol with molybdenum(Ⅲ) in alkaline condition, a method of flow injection-electrochemiluminescence for the determination of trace amount of molybdenum in coal ash was proposed. Linear relationship between values of increase in CL intensity and mass concentration of molybdenum(Ⅵ) was obtained in the range of 5.0×10-7-5.0×10-4g·L-1, with detection limit (3s/k) of 5×10-8g·L-1. Values of RSD (n=11) obtained for molybdenum(Ⅵ) at a concentration of 1.0×10-6g·L-1 was 2.6%. The proposed method was applied to the determination of molybdenum in coal ash, giving results in consistency with those obtained by the GB standard method.