磁固相萃取-高效液相色谱法测定环境水样中双酚A
HPLC Determination of Bisphenol A in Environmental Water Samples with Magnetic Solid Phase Extraction
-
摘要: 采用磁固相萃取-高效液相色谱法测定环境水样中双酚A的含量.优化的试验条件如下:① 50 mL水样中加入20 mg磁性微球进行萃取;② 水样的pH为3.0;③ 萃取时间为15 min;④ 解析溶剂为甲醇(80+20)溶液;⑤ 解析时间为10 min.采用C18色谱柱为分离柱,以甲醇-水(85+15)混合液为流动相,在检测波长224 nm处进行测定.双酚A的质量浓度在5.0~500 μg·L-1范围内与其峰面积呈线性关系,方法的检出限(3S/N)为1.0 μg·L-1.方法应用于环境水样的分析,加标回收率在81.4%~109%之间,测定值的相对标准偏差(n=6)在5.7%~8.6%之间.Abstract: HPLC was applied to the determination of bisphenol A in environmental water samples with magnetic solid phase extraction. The optimized conditions found were as follows:① 50 mL water sample was extracted with 20 mg magnetic microsphere;② pH of water sample:3.0;③ time of extraction:15 min;④ desorption solution:methanol (80+20) solution;⑤ desorption time:10 min. The C18 chromatographic column was used as stationary phase,and a mixture of methanol and water (85+15) was used as mobile phase. UV-detection at 224 nm was adopted in the determination. Linear relationship between values of peak area and mass concentration of bisphenol A was kept in the range of 5.0-500 μg·L-1,with detection limit (3S/N) of 1.0 μg·L-1. The proposed method was applied to the analysis of environmental water samples,giving values of recovery and RSD′s (n=6) in the ranges of 81.4%-109% and 5.7%-8.6%,respectively.