高级检索

    离子色谱法测定复混肥料中氯离子含量

    IC Determination of Chloride Ion in Compound Fertilizers

    • 摘要: 按国标GB 15063-2001所述处理样品.取10 mL滤液稀释50倍,使Cl-浓度保持在约20 mg·L-1.注入高交换容量Dionex Ionpac AS 23阴离子色谱柱,用0.8 mmol·L-1碳酸氢钠和4.5 mmol·L-1碳酸钠混合溶液作等度淋洗,流量为1.0 mL·min-1,用抑制电导检测,保留时间定性,外标法峰面积定量,在5.0~50.0 mg·L-1范围内氯离子浓度与色谱峰面积呈线性关系,加标回收率在87.2%~104.9%之间.分析结果的平均值与国标法测定值相符.

       

      Abstract: Sample of compound fertilizer was treated as described in GB 15063-2001,and 10 mL aliquot of the filtrate were diluted 50 times to keep the mass concentration of Cl- at ca.20 mg·L-1.The Dionex Ionpac AS 23 column was used as stationary phase and the mixture of 0.8 mmol·L-1 NaHCO3 solution and 4.5 mmol·L-1 Na2CO3 solution was used as the mobile phase in the elution at the flow-rate of 1.0 mL·min-1.Suppression conductivity detection was used in measurements.Retention time was used for identification,and external standard method was used in determination.Linear relationship between values of peak area and mass concentration of Cl- ion was kept in the range of 5.0 to 50.0 mg·L-1.Recovery was tested by standard addition method,giving values of recovery in the range of 87.2% to 104.9%.Samples of compound fertilizer were analyzed by the present method and checked by the method of National standard,results obtained were found in good consistency.

       

    /

    返回文章
    返回