Advanced Search
    XING Yuan-na, FENG An-hong, LIN Zhi-hui, WANG Xin, GONG Ye-meng, CHEN Ze-yong. GC-MS Determination of Polychlorinated Biphenyls in Polymer Materials Used in Electrical and Electronic Products[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART B:CHEMICAL ANALYSIS, 2015, 51(11): 1547-1551. DOI: 10.11973/lhjy-hx201511013
    Citation: XING Yuan-na, FENG An-hong, LIN Zhi-hui, WANG Xin, GONG Ye-meng, CHEN Ze-yong. GC-MS Determination of Polychlorinated Biphenyls in Polymer Materials Used in Electrical and Electronic Products[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART B:CHEMICAL ANALYSIS, 2015, 51(11): 1547-1551. DOI: 10.11973/lhjy-hx201511013

    GC-MS Determination of Polychlorinated Biphenyls in Polymer Materials Used in Electrical and Electronic Products

    • GC-MS was applied to the determination of polychlorinated biphenyls in polymer materials used in electrical and electronic products. The sample was extracted ultrasonically with a mixture of acetone and n-hexane (1+1). The extract was purified with a solid phase extraction column filled with neutral sllica gel and then separated on a DB-5MS UI capillary column. EI and SIM were adopted in MS. The linearity ranges of polychlorinated biphenyls (Cl1-Cl10) were all 0.1-10 mg·L-1,with the same lower limits of determination (10S/N) of 0.1 mg·kg-1. Recovery rates obtained by standard addition method were in the range of 86.0%-109%,and RSDs (n=7) were within 10%.