Advanced Search
    ZHANG Ke, FENG Yindi, LIU Shouwei, YANG Xiaolong, FU Huicheng, SUN Yiting, MA Yunfei, LIU Shuangying, MA Zhuoqi. IC Determination of Cl- and SO42- in Water Samples of Hydraulic Engineering[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART B:CHEMICAL ANALYSIS, 2017, 53(5): 607-610. DOI: 10.11973/lhjy-hx201705027
    Citation: ZHANG Ke, FENG Yindi, LIU Shouwei, YANG Xiaolong, FU Huicheng, SUN Yiting, MA Yunfei, LIU Shuangying, MA Zhuoqi. IC Determination of Cl- and SO42- in Water Samples of Hydraulic Engineering[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART B:CHEMICAL ANALYSIS, 2017, 53(5): 607-610. DOI: 10.11973/lhjy-hx201705027

    IC Determination of Cl- and SO42- in Water Samples of Hydraulic Engineering

    • Water sample of hydraulic engineering was filtered, and separated by IC, using TSKgel IC-Anion-PWXL PEEK anionic column as separation column, and 2.5 mmol·L-1 sodium tetraborate solution (pre-adjusted to pH 10.5 with ethylenediamine) as eluant. Non-restrain conductance detector was used in the determination. Linear relationships between values of peak area and mass concentration of Cl- and SO42- were kept in the same range of 2.50-50.00 mg·L-1, with detection limits (3S/N) of 5.1, 7.6 μg·L-1 respectively. Precision of the method was tested with blank water sample for 5 determinations, values of RSD's (in terms of peak area) found for Cl- and SO42- were 4.1% and 2.3%, respectively. Values of recovery found by standard addition method were in the range of 97.9%-102%.
    • loading

    Catalog

      Turn off MathJax
      Article Contents

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return
      Return