Advanced Search
    WANG Peng, LONG Shaojun, LIAO Zhihai, QIAO Hongbo, WANG Zhanming, ZHAO Feng, NING Wei. ICP-MS Determination of W in Nuclear Grade Sponge Zirconium[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART B:CHEMICAL ANALYSIS, 2017, 53(11): 1322-1324. DOI: 10.11973/lhjy-hx201711017
    Citation: WANG Peng, LONG Shaojun, LIAO Zhihai, QIAO Hongbo, WANG Zhanming, ZHAO Feng, NING Wei. ICP-MS Determination of W in Nuclear Grade Sponge Zirconium[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART B:CHEMICAL ANALYSIS, 2017, 53(11): 1322-1324. DOI: 10.11973/lhjy-hx201711017

    ICP-MS Determination of W in Nuclear Grade Sponge Zirconium

    • The sample (0.100 0 g) of nuclear grade sponge zirconium was dissolved with HF (0.5 mL) and HNO3 (2 mL) at temperature of 150℃ or so,and then was diluted to 100 mL with water. ICP-MS was applied to the determination of W in the sample solution. 184W was used as the analytical nuclide, 232Th was used as internal standard. Linearity range of W was found in the range within 100.0 μg·L-1 with detection limit (3s) of 0.003 μg·L-1. Tests for recovery was made by standard addition method at the concentration levels of 2.00, 50.00 μg·L-1, values of recovery found were 91.5%,93.5%, with RSD's (n=6) of 5.0%, 2.4%.
    • loading

    Catalog

      Turn off MathJax
      Article Contents

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return
      Return