Determination of Five Kinds of Food Additives in Meat Products by Ion Chromatography
-
Graphical Abstract
-
Abstract
Ion chromatography was applied to simultanous determination of nitrite, nitrate, sorbic acid, and benzoic acid, acesulfame in meat products. The sample (1.000 0 g) was extracted with 10 mL of 20 mmol·L-1 NaOH solution, and the extrate was filtrated with OnGuard Ⅱ Ag solid phase extraction column and 0.22 μm filter. The analytes were separated by using IonPac AS 19 anion-exchange analytical column and IonPac AG 19 guard column, with KOH solution for gradient elution, and detected with a conductivity detector.The linearity ranges of the five kinds of food additives were same 0.2-8.0 mg·L-1, with detection limits (3S/N) of 10, 15, 60, 50, 11 μg·kg-1 for nitrite, nitrate, sorbic acid, benzoic acid and acesulfame, respectively. Recovery rates obtained by standard addition method were in the range of 82.5%-111% and RSDs (n=6) were less than 9.0%.
-
-