Advanced Search
    TANG Molan, BAO Zhengyu, FAN Bolun, MA Zhenzhen, MA Ming, LIU Man. HG-AFS Speciation Analysis for 5 Species of Selenium in Se-Rich Soil with Separation by Sequential Extraction[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART B:CHEMICAL ANALYSIS, 2018, 54(4): 408-412. DOI: 10.11973/lhjy-hx201804008
    Citation: TANG Molan, BAO Zhengyu, FAN Bolun, MA Zhenzhen, MA Ming, LIU Man. HG-AFS Speciation Analysis for 5 Species of Selenium in Se-Rich Soil with Separation by Sequential Extraction[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART B:CHEMICAL ANALYSIS, 2018, 54(4): 408-412. DOI: 10.11973/lhjy-hx201804008

    HG-AFS Speciation Analysis for 5 Species of Selenium in Se-Rich Soil with Separation by Sequential Extraction

    • The sequential extraction was modified and applied to the speciation analysis of 5 species of selenium in samples of Se-rich soil by HG-AFS. For separation of the 5 species (i.e., the water-soluble species, the exchangeable species, the organic-bound species, the acid-soluble species and the residual species), 0.500 g of the soil sample was taken and extracted in succession by swirling with 20 mL of water, 10 mL of 0.1 mol·L-1 K2HPO4-KH2PO4 buffer solution (pH 7.0), 20 mL of 0.1 mol·L-1 NaOH solution and 10 mL of 3 mol·L-1 HCl solution. After each extraction, the mixtures were centrifuged, the supernatants containing respectively the former 4 species were reserved for HG-AFS determinations, and the residues were collected for the next extraction. The residue, remained after the 4th extraction, was dried and transferred into a PTFE vessel, and digested with 1 mL of HNO3, 0.5 mL of HF and 0.5 mL of HClO4 under tight closing and pressure. After digestion, the PTFE vessel was cooled and taken out, and the solution in it was evaporated to dryness. The residue was taken up with 1 mL of 6 mol·L-1 HCl solution and let Se(Ⅵ) be reduced to Se(Ⅳ). The solution was diluted to 10.0 mL with water, and residual species of Se were determined by HG-AFS. The supernants, obtained in the former 3 extractions, should be treated separately to convert into solutions of 10 mL with concentration of 0.6 mol·L-1 HCl, before used for HG-AFS analysis. Amounts of Se found in the 5 solutions, represented the contents of 5 species of Se in the soil sample. Value of detection limit (3s/k) found was 0.21 μg·L-1, and RSDs (n=6) found were all less than 11%. Recovery found by standard addition were ranged from 91.7% to 107%.
    • loading

    Catalog

      Turn off MathJax
      Article Contents

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return
      Return