Advanced Search
    LIU Xuemin, GAN Wei, ZHA Yangjing, GAN Jun, QIAO Lei. GC-MS Determination of 36 Volatile Organic Compounds in Surface Coating Exhaust Gas with Sorbent Adsorption and Thermal Desorption[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART B:CHEMICAL ANALYSIS, 2019, 55(11): 1297-1304. DOI: 10.11973/lhjy-hx201911010
    Citation: LIU Xuemin, GAN Wei, ZHA Yangjing, GAN Jun, QIAO Lei. GC-MS Determination of 36 Volatile Organic Compounds in Surface Coating Exhaust Gas with Sorbent Adsorption and Thermal Desorption[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART B:CHEMICAL ANALYSIS, 2019, 55(11): 1297-1304. DOI: 10.11973/lhjy-hx201911010

    GC-MS Determination of 36 Volatile Organic Compounds in Surface Coating Exhaust Gas with Sorbent Adsorption and Thermal Desorption

    • The sample of surface coating exhaust gas was concentrated with sorbent adsorption. After thermal desorption, GC-MS was applied to the determination of 36 volatile organic compounds in surface coating exhaust gas. The SH-Rtx-624 chromatographic column was used for GC separation and the full scanning mode was adopted in MS determination. Internal standard method was used for quantitative. Detection limits (3S/N) of the 36 volatile organic compounds were in the range of 0.018-2.96 ng. On the base of blank sample, test for recovery was made by standard addition method; values of recovery found were in the range of 84.5%-111%, with RSDs (n=6) of determined values in the range of 1.7%-14%.