Advanced Search
    ZHENG Zhenhao, WU Shuchao, DING Siyuan, WANG Qinhao, XU Junkai, SUN Chaoyang. Determination of 3-Nitrophenol and 4-Nitrophenol in Surface Water by High Performance Liquid Chromatography Combined with Fluorescence Detector after Online pre-Column Reduction[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART B:CHEMICAL ANALYSIS, 2024, 60(9): 927-931. DOI: 10.11973/lhjy-hx240399
    Citation: ZHENG Zhenhao, WU Shuchao, DING Siyuan, WANG Qinhao, XU Junkai, SUN Chaoyang. Determination of 3-Nitrophenol and 4-Nitrophenol in Surface Water by High Performance Liquid Chromatography Combined with Fluorescence Detector after Online pre-Column Reduction[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART B:CHEMICAL ANALYSIS, 2024, 60(9): 927-931. DOI: 10.11973/lhjy-hx240399

    Determination of 3-Nitrophenol and 4-Nitrophenol in Surface Water by High Performance Liquid Chromatography Combined with Fluorescence Detector after Online pre-Column Reduction

    • A method for determination of 3-nitrophenol and 4-nitrophenol in surface water by high performance liquid chromatography combined with fluorescence detector after online pre-column reduction was proposed. 500 mL of water sample was placed into a separating funnel, and 30 g of sodium chloride was added. The pH of the mixture was adjusted to less than 2 with 10% (mass fraction) hydrochloric acid solution. 40 mL of a mixture of dichloromethane and ethyl acetate at a volume ratio of 1∶1 was added, the mixture was shaken for 5 min and then settled, and the organic phase was collected, which was extracted repeatly 3 times. The organic phases were combined, and dehydrated with anhydrous sodium sulfate. The extract was collected, and rotary evaporated to near dryness at 40 ℃ under 79 kPa. The residue was re-dissolved and made its volume up to 1.0 mL with methanol. Hypersil GOLD chromatography column was connected with a zinc powder reduction column of packing particle size of 70 µm, and methanol solution containing 0.39 g·L−1 acetic acid, 0.53 g·L−1 zinc acetate,and 0.083 g·L−1 copper sulfate was used as mobile phase for separation. The reduction products of 3-nitrophenol and 4-nitrophenol were determined by fluorescence detector. As shown by the results, linear relationships between the peak areas of the corresponding reduction products and mass concentrations of 3-nitrophenol and 4-nitrophenol were found within 10-100 µg·L−1, with detection limits (3S/N) of 3.0, 1.5 µg·L−1, respectively. Test for recovery was made by the standard addition method, giving results in the range of 80.0%-92.6%, with RSDs (n=6) of the determined values not more than 11%.
    • loading

    Catalog

      Turn off MathJax
      Article Contents

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return
      Return