GC DETERMINATION OF DIMETHYLACETAMIDE,BUTANONE AND DECANE IN THE AIR OF WORKSHOP
-
Graphical Abstract
-
Abstract
Dimethylacetamide (DMAM),butanone (BN) and decane (DC) in the air of workshop were sampled using Tenax absorption tube,and then desorbed in the thermo-desorption furnace at 300 ℃ for 40 s.The compounds in the gaseous state were introduced into the GC-analytical system by the carrier gas,and separated on the SE 30 capillary chromatographic column.The determination of the concentrations of the 3 compounds were performed by the measurement of their peak area and by the external standard method.The correlation coefficients of the linear regression equations for the 3 compounds were larger than 0.992.Absorption rates of the Tenax absorption tube for the 3 compounds were over 90%,and their rate of desorption were over 85%.Average recoveries obtained in the test for recovery were in the range of 85% to 110%.
-
-