    HU Xiao-gui, XIE Su-wen. DETERMINATION OF TRACE AMOUNTS OF IRON(Ⅲ) BY CATALYTIC KINETICS SPECTROPHOTOMETRY[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART B:CHEMICAL ANALYSIS, 2006, 42(3): 203-204.
    Citation: HU Xiao-gui, XIE Su-wen. DETERMINATION OF TRACE AMOUNTS OF IRON(Ⅲ) BY CATALYTIC KINETICS SPECTROPHOTOMETRY[J]. PHYSICAL TESTING AND CHEMICAL ANALYSIS PART B:CHEMICAL ANALYSIS, 2006, 42(3): 203-204.

    DETERMINATION OF TRACE AMOUNTS OF IRON(Ⅲ) BY CATALYTIC KINETICS SPECTROPHOTOMETRY

    • Based on the catalytic effect of trace amounts of iron(Ⅲ)on the oxidation of methyl orange by hydrogen peroxide in a dilute nitric acid solution,a new kinetic photometric method for the determination of traces of iron(Ⅲ) was established.The sensitivity of method is 0.015 μg·L-1 and the linear range of determination is 0-96 μg·L-1.The method has been applied to the determination of trace amounts of iron(Ⅲ) in sample of activated carbon with recoveries in the range from 99% to 105%.