Page 85 - 理化检验-化学分册2024年第十二期
P. 85
李支薇,等:高效液相色谱法测定涂料中3种含氟烷基丙烯酸酯化合物的含量
231. European Committee for Standardization,2022.
[19] Comité Européen de Normalisation. Textiles and [20] 吴坤,吴玉田,赵君,等. 滤过型固相萃取柱净化-超
textile products-organic fluorine part 2:Determination 高效液相色谱-串联质谱法测定鸡蛋中 15 种全氟化
of volatile compounds by extraction method using gas 合物的含量[J]. 理化检验-化学分册,2024,60(1):
chromatography:EN 17681-2:2022[S]. Brussels: 60-66.
Determination of 3 Fluoroalkyl Acrylate Compounds in Coating by
High Performance Liquid Chromatography
LI Zhiwei , ZHANG Lanlan , LI Yong , ZHONG Lin , QIN Yumei 1
1*
1
3
2
(1. GRG Metrology & Test Group Co., Ltd., Guangzhou 510700, China; 2. CRRC Changchun Railway Vehicles Co., Ltd.,
Changchun 130062, China; 3. AIE Institute, Guangzhou 510700, China)
Abstract: The 2. 000 g of coating sample was taken, and 15 mL of acetonitrile was added. The mixture was vortexed
for 30 s, and extracted by ultrasound at 30 ℃ for 40 min. After cooling to room temperature, the extract was made its volume
up to 20 mL with acetonitrile. An aliquot (1 mL) was taken, and passed through a 0. 22 μm filter membrane, and the filtrate
was introduced into a high performance liquid chromatograph. Three fluoroalkyl acrylate compounds (FTAs), including
1H,1H,2H,2H-perfluorodecyl acrylate (8∶2 FTA), 1H,1H,2H,2H-perfluorododecyl acrylate (10∶2 FTA), and 1H,1H,2H,2H-
perfluorooctyl acrylate (6∶2 FTA) were separated on a ZORBAX SB-Aq column by gradient elution with a mixture of acetonitrile
and water at different volume ratios, with external standard method for quantification. It was shown that linear relationships
−1
between values of mass concentration and peak area of the 3 FTAs were kept in the range of 0. 2-5. 0 mg · L , and the detection
limits (3S/N) were found in the range of 0. 27-0. 34 mg · kg −1 . Test for recovery was made according to the standard addition
method, giving recoveries in the range of 93. 5%-109%, with RSDs (n=6) of the determined values ranged from 0. 50% to
4. 7%. The proposed method was used for the analysis of 10 types of coating samples, and 8∶2 FTA was detected in two types of
samples, with detection amounts of 226. 7 mg · kg −1 and 4. 1 mg · kg −1 , respectively.
Keywords: fluoroalkyl acrylate compound; high performance liquid chromatography; coating
• 1279 •