Page 65 - 理化检验-化学分册2025年第三期
P. 65
陈嘉科,等:高效液相色谱法同时测定精氨酸布洛芬片剂中布洛芬和精氨酸的含量
ZHANG H,YANG J R,GAO S C,et al. HPLC [22] 戴静波,吴翠莉,叶红. 高效液相色谱法测定布洛芬
analysis of arginine ibuprofen spray[J]. Journal of Tianjin 颗粒的含量[J]. 中国医院药学杂志,2006,26(12):
Medical University,2010,16(2):229-231. 1580-1581.
[20] 郭志辉,张庆伟,王润玲. HPLC法测定精氨酸布洛芬 DAI J B,WU C L,YE H. Determination of
分散片含量[J]. 药物分析杂志,2005,25(8):990-991. ibuprofen granules by high performance liquid
GUO Z H,ZHANG Q W,WANG R L. HPLC chromatography[J]. Chinese Journal of Hospital
determination of arginine ibuprofen dispersible Pharmacy,2006,26(12):1580-1581.
tablets[J]. Chinese Journal of Pharmaceutical Analysis, [23] WANG S,SONG Z Q,WANG J D,et al. Solubilities
2005,25(8):990-991. of ibuprofen in different pure solvents[J]. Journal of
[21] 王家满,王浩,韩琼,等. 高效液相色谱法测定布洛 Chemical & Engineering Data,2010,55(11):5283-
芬注射液中精氨酸的含量[J]. 湖北中医药大学学报, 5285.
2014,16(4):55-56. [24] LOMBA L,GARRALAGA M P,WERNER Á,
WANG J M,WANG H,HAN Q,et al. Determination et al. Ibuprofen solubility and cytotoxic study of deep
of arginine in ibuprofen injection by HPLC[J]. Journal eutectic solvents formed by xylitol,choline chloride
of Hubei University of Chinese Medicine,2014,16(4): and water[J]. Journal of Drug Delivery Science and
55-56. Technology,2023,82:104327.
Simultaneous Determination of Ibuprofen and Arginine in Arginine Ibuprofen
Tablets by High Performance Liquid Chromatography
CHEN Jiake, ZHANG Zhi, XU Yang, WU Jia, LI Lin *
(Yanjing Medical College, Capital Medical University, Beijing 101300, China)
Abstract: Arginine ibuprofen tablets were taken, removed the coating, and ground. The power was dissolved in a mixture
of acetonitrile and water at the volume ratio of 8∶2. The main drug ibuprofen and the key excipient arginine in arginine ibuprofen
tablets were determined by high performance liquid chromatography (HPLC), using Dikma Silversil C 18 bonded silica gel column
(250 mm×4. 6 mm, 5. 0 μm) as the stationary phase, and the mixed solution composed of acetonitrile and water (water adjusted
to pH 2. 5 with phosphoric acid) at the volume ratio of 8∶2 as the mobile phase. The photodiode array detector was used to
detect ibuprofen at 230 nm and arginine at 208 nm, and the standard curve method was used for quantitative analysis. As shown
by the results, ibuprofen could be completely separated from arginine under the optimized chromatographic conditions. Linear
relationships between the corresponding peak areas and mass concentrations of ibuprofen and arginine were found in definite
−1 −1
ranges, with detection limits (3S/N) of 0. 45 mg · L and 18 mg · L , respectively. RSDs (n=6) of the determined values in the
precision test were less than 3. 0%. It was shown by the stability test results that the mixed reference solution and sample solution
were stable within 24 h at room temperature. And the recoveries were in the ranges of 99. 1%-102% for ibuprofen and 97. 4%-
102% for arginine, respectively.
Keywords: arginine; ibuprofen; tablet; high performance liquid chromatography (HPLC)
• 299 •